Description: Fast ShippingOn All Items 30 Days MoneyGuarantee Customer SupportExcellent Service 100% SatisfactionSatisfaction Guaranteedsquare d main breaker box 100 amp 30-space 60-circuit indoor neutral load centerSpecification Electrical Product Type Load Center Indoor/Outdoor Indoor Load Center Mounting Type Flush,Surface Load Center Type Main Breaker Maximum Amperage (A) 100 Mounting Type Plug-On Neutral NEMA Configuration NEMA 1 NEMA Configuration Receptacle No Receptacle Number of Circuits 60 Number of Spaces 30 Phase Type 1 Phase Product Weight (lb) 30.32 Returnable 90-Day Voltage (V) 120/240 Certifications and Listings UL Listed Manufacturer Warranty warrants its single phase load centers, in a residential application, to be free from defects in material and workmanship under normal care and proper usage for a period of 10 years from the date of installation for HOMELINE load centers when used with the appropriate HOMELINE branch circuit breakers. Load center depth (in) 3.75 Load center height (in) 33.78 Load center width (in) 14.25 14.25 inches x 3.75 inches x 33.78 inches. Weight: 30.32 lb Item DescriptionLess wiring, clean gutter, fast installation with Plug-On NeutralCompatible with any Square D Homeline circuit breakerIncludes combination flush/surface cover and aluminum bus bar The Square D Homeline 100 Amp 30-Space 60-Circuit Indoor Convertible Main Breaker Load Center with cover for Plug-on Neutral breakers is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and is compatible with Square D Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Square D Homeline breaker boxes are engineered for fast installation and wire savings.Square D Homeline 100 Amp 30-Space 60-Circuit Indoor Main Breaker Plug-On Neutral Load Center with CoverIncludes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral combination arc fault breakers on any spaceEach pole space accepts full-size, tandem or quad Square D Homeline breakersGround and neutral bars accept up to (3) #10-14 equipment groundsIncludes a combination flush/surface indoor coverAccommodates plug-on secondary surge arrestor (sold separately)Overhead/underground feed simply by rotating the device before installingSingle phase, for indoor installationRated 120/240 VAC and 22,000 AIR short circuit current ratingAutomatic flush adjusting cover requires less time to complete the jobDesigned with straight-in mains to save expensive cable and timeDistributed split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiringThermoplastic interior assembly is among the most rugged in the industrySlot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torqueFor protection from damage or theft on the job site, interiors can be easily removed with a single captive screw3 ground bar mounting locations (left, right and end) let you pick the easiest spot to wireMade in the USA About us We offer the best prices around on high quality products. Our E-store includes media such as books, movies, music and games while offering electronics, toys, sporting apparel, clothing, tools, general home, garden items and more. Shipping We are always working hard to ensure your package arrives as soon as possible. Please understand that some factors like weather, high postal traffic, and the performance of shipping companies are outside of our control.We offer free shipping to the lower 48 states and ship within 2-3 business days of payment, usually sooner. We do not accept P.O. Boxes. Please provide a physical address.For shipping outside of the continental USA, we only use eBays Global Shipping Program.The item is shipped to KY and then sent to the rest of the world. International customers are responsible for all duties and taxes. Continue to check out to calculate costs for shipping the item to your country. Messages regarding eBays Global Shipping Program MUST be directed at eBay EXCLUSIVELY. Returns We offer a 30-Day Return Policy on items in which you are not completely satisfied with. You have the option of a full-refund or an exchange of the item. No returns are available on items shipped outside of the USA Satisfaction We try over very best to make sure every customer is completely satisfied. If theres a problem, message us! Were happy to help.Payment OptionsShop With Confidence
Price: 163.9 USD
Location: Houston, Texas
End Time: 2023-11-30T13:00:47.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Brand: Does not apply
Electrical Product Type: Load Center
Indoor/Outdoor: Indoor
Load Center Mounting Type: Flush,Surface
Load Center Type: Main Breaker
Maximum Amperage (A): 100
Mounting Type: Plug-On Neutral
NEMA Configuration: NEMA 1
NEMA Configuration Receptacle: No Receptacle
Number of Circuits: 60
Number of Spaces: 30
Phase Type: 1 Phase
Product Weight (lb): 30.32
Returnable: 90-Day
Voltage (V): 120/240
Certifications and Listings: UL Listed
Manufacturer Warranty: warrants its single phase load centers, in a residential applicat
Load center depth (in): 3.75
Load center height (in): 33.78
Load center width (in): 14.25
Type: Does not apply