Description: MA9070 Description The MA9070 Zero Oxygen Calibration Solution Kit is made up of two components for use in calibrating the Milwaukee MW600 DO Meter. Design Features Easy to use Simple mix the two components and place in solution to quickly calibrate to 0% oxygen concentration Traceable Product labeled with product code, lot number and expiration date Secure Air tight bottle with tamper-proof seal Specifications Package: Bottle Size: 500 mL Quantity: 1 Certificate of Analysis: On request MA9071 Description The MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe. Design Features Precise formulation Factory mixed using reagent grade chemicals in a dedicated, temperature controlled environment. Traceable Product labeled with product code, lot number and expiration date. Secure Air tight bottle with tamper-proof seal. Use and Care “Open Air” Calibration Procedure for the MW600 Dissolved Oxygen Meter 1. Remove the membrane Take the membrane off the end of the probe and dry the diode off. 2. Zero out the display Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0. 3. Fill the membrane Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure) 4. Attach the membrane Screw the membrane on to the probe. 5. Let stablize Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes) 6. Adjust Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100. You are now calibrated. Extra tips Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane. Always use fresh electrolyte solution (MA9071). Specifications Package: Bottle Size: 230 mL Quantity: 1 Certificate of Analysis: No
Price: 65.95 USD
Location: Elgin, South Carolina
End Time: 2024-08-27T13:51:18.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Milwaukee
Model: MA9070-MA9071
MPN: MA9070-71