Description: HP/Agilent 8591E Spectrum Analyzer w/Opt 010, 041. 9 kHz to 1.8 GHz Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from HP/Agilent and may vary slightly due to upgrades, options, or revisions this unit may or may not have. This unit is sold fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. The Unit's Serial Number Tag Reads: Serial Number: 3624U02048 Installed Options: Option 010: Tracking Generator (50Ω) Option 041: GPIB and Parellel Printer Interfaces Description: The Agilent 8591E is an easy-to-use RF spectrum analyzer that offers a wide range of performance, features, and optional capability to meet your measurement needs. Downloadable measurement personalities combine with optional plug-in performance to provide tailored solutions for your application. Perform complex tests simply and quickly with measurement personalities that support applications like cable TV/broadcast, component test, electromagnetic compatibility, lightwave, and wireless communications Four slot cardcage Split screen display One-button measurement routines Advanced measurement functions Dual interfaces Built-in tracking generator E4444A BenchLink software - (Purchasable for $426 from Agilent) Frequency Specifications: Frequency Range: 9 kHz to 1.8 GHz Frequency Reference: Aging: ±2 x 10-6/year Temperature Stability: ±5 x 10-6 Initial Achievable Accuracy: ±0.5 x 10-6 Frequency Readout Accuracy (start, stop, center, marker): ±(freq. readout x freq. ref error + span accuracy + 1% of span + 20% of RBW + 100 Hz x N) Marker Count Accuracy: Span < or = to 10 MHz x N: ±(marker freq. x freq. ref error + counter resolution + 100 Hz x N) Span > 10 MHz x N: ±(marker freq. x freq. ref error + counter resolution + 1 kHz x N) Counter Resolution: Span < or = to 10 MHz x N: Selectable from 10 Hz to 100 kHz Span > 10 MHz x N: Selectable from 100 Hz to 100 kHz Frequency Span: Range: 0 Hz (zero span) and HP 8591E: 10 kHz to 1.8 GHz Resolution: Four digits or 20 Hz x N, whichever is greater Accuracy: Span < or = to 10 MHz x N: ±2% of span Span > 10 MHz x N: ±3% of span Sweep Time: Range: Span = 0 Hz or > 1 kHz: 20 ms to 100 s Accuracy: 20 ms to 100 s: ±3% Sweep Trigger: Free run, single, line, video, external Resolution Bandwidth: 1 kHz to 3 MHz (3 dB) in 1, 3, 10 sequence; 9 kHz and 120 kHz (6 dB) EMI bandwidths Accuracy: ±20% Selectivity (characteristics): -60 dB/-3 dB: 3 kHz to 10 kHz, 15:1. 100 kHz to 3 MHz, 15:1 -40 dB/-3 dB: 30 Hz to 300 Hz, 10:1 Vision Bandwidth Range: 30 Hz to 1 MHz in 1, 3 sequence Stability: Noise Sidebands (1 kHz RBW, 30 Hz VBW, Sample Detector): > 10 kHz offset from CW Signal: < or = to -90 dBc/Hz + 20 log N > 20 kHz offset from CW Signal: < or = to -100 dBc/Hz + 20 log N > 30 kHz offset from CW Signal: < or = to -105 dBc/Hz + 20 log N Residual FM: 1 kHz RBW, 1 kHz VBW: < or = to 250 Hz pk-pk in 100 ms 30 Hz RBW, 30 Hz VBW: < or = to 30 Hz pk-pk in 300 ms System Related Sidebands (> 30 kHz offset from CW signal): < or = to -65 dBc + 20 log N Amplitude Specifications: Amplitude Range: Displayed average noise level to +30 dBm Maximum Safe Input Level (input attenuator > or = to 10 dB): Average Continuous Power: +30 dBm (1 W) Peak Pulse Power: ±30 dBm (1 W) DC: 25 VDC Gain Compression (> 10 MHz): < or = to 0.5 dB (total power at input mixer = -10 dBm) Displayed Average Noise Level (input terminated, 0 dB atten., 30 Hz VBW or 1 Hz VBW with option 130, sample detector): 30 Hz RBW:1 kHz RBW:400 Hz to 1 MHz:< or = to -130 dBM< or = to -115 dBM1 MHz to 1.5 GHz:< or = to -130 dBM< or = to -115 dBM1.5 GHz to 1.8 GHz:< or = to -128 dBM< or = to -113 dBM Spurious Responses: Second Harmonic Distortion (5 MHz to 1.8 GHz): < -70 dBc for - 45 dBm tone at input mixer Third Order Intermodulation (5 MHz to 1.8 GHz): < -70 dBc for two -30 dBm tones at input and > 50 kHz separation Other Input-Related Spurious (30 kHz offset, -20 dBm tone at input mixer): < -65 dBc Display Range: Log Scale: 0 to -70 dB from ref level is calibrated; 0.1, 0.2, 0.5 dB/div and 1 to 20 dB/div in 1 dB steps; 8 div displayed Linear Scale: 8 divisions Scale Units: dBm, dBmV, dBµV, V, W Marker Readout Resolution: Log Scale: 0.05 dB Linear Scale: 0.05% of ref level Reference Level: Range: Same as amplitude range Resolution: ±0.01 dB for log scale; ±0.12% of ref level for linear scale Accuracy: ±0.3 dB at -20 dBm; 0 to -59.9 dBm: ±(0.3 dB + 0.01 x dB from -20 dBm) Frequency Response (10 dB Input Attenuation): Absolute (referenced to 300 MHz CAL OUT): ±1.5 dB Relative Flatness (referenced to midpoint between highest and lowest frequency response deviations): ±1.0 dB Resolution Bandwidth Switching Uncertainty (ref to 3 kHz RBW, at ref level): 3 kHz to 3 MHz RBW: ±0.4 dB 1 kHz RBW: ±0.5 dB 30 Hz to 300 Hz RBW: ±0.6 dB Log to Linear Switching: ±0.25 dB at ref level Display Scale Fidelity: Log Incremental Accuracy (0 to -60 dB from ref level): ±0.4 dB/4 dB Log Maximum Cumulative (0 to -70 dB from ref level): 3 kHz to 3 MHz RBW: ±:(0.3 + 0.01 x dB from ref level) 30 Hz to 1 kHz RBW: ±(0.4 + 0.01 x dB from ref level) Linear Accuracy: ±3% of ref level General Specifications: MIL-T-28800: Has been type-tested to the environmental specifications of MIL-T-28800 Class 5 Temperature: Operating: 0° to +55°C Storage: -40° to +75°C EMI Compatibility: Conducted and radiated interference CISPR Pub. 11 and Messemfaenger Postverfuegung 526/526/79 Audible Noise: < 37.5 dBA pressure and < 5.0 Beis power (ISODP7779) Power Requirements: ON (Line 1): 90 to 132 V rms, 47 to 440 Hz, 195 to 250 V rms, 47 to 66 Hz. Power consumption < 500 VA; < 180 W Standby (Line 0): Power consumption < 7 W User Program Memory (Nominal): 238 KB nonvolatile RAM Data Storage (Nominal): Internal: 24 traces or 32 states External: 50 traces, 8 states Memory Cards: HP 85700A (32 KB), 24 traces or 32 states; HP 85702A (128 KB), 99 traces or 128 states Video Cassette Recorder (VCR): Continuous video recording of display supported through composite video output Size (Nominal, without handle, feet, or cover): 325 mm W x 163 mm H x 427 mm D Weight: 14.5 kg Option 010 Built-in Tracking Generator Specifications: Frequency Range: 100 kHz to 1.8 GHz Output Level: Range: 0 to -70 dBm Resolution: 0.1 dB Absolute Accuracy: ±0.1 dB Vernier: Range: 10 dB Accuracy: ±0.75 dB Output Flatness: ±1.75 dB Spurious Output: Harmonic Spurs: 0 dBm +42.8 dBmV output, < -25 dBc Nonharmonic Spurs: < -30 dBc Dynamic Range (Characteristic; max. output level - TG feedthrough): 106 dB Power Sweep: Range: -75 dBm to 0 dBm Resolution: 0.1 dB For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $75.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? 12/31/12
Price: 2999.99 USD
Location: Phoenix, Arizona
End Time: 2024-02-29T23:30:58.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Model: 8591E
Product: Benchtop Spectrum Analyzer
Installed Options: 010, 041
Manufacturer: HP
Analyzer Type: Spectrum Analyzers
MPN: 8591E
Unit Type: Complete Systems & Mainframes
Brand: HP
Frequency Range: 9 kHz to 1.8 GHz