Description: Dear friend, We are facotry,any product can give you 10% discount, please contact me Whatsapp:+8615243475232,conteccare AT gmail com Introduction E3 is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc. Function 1)High resolution thermal-array output system(8 dots/mm), no adjustment required. Frequency Response is up to 150Hz. 2)Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal. 3)Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing. 4)Support for auto 1×12, auto 1×12+1, auto 2×6, auto 2×6+1, auto 3×4, auto 3×4+1, auto 4×3, auto 3-2+1, auto 3-2, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, paper speed, sensitivity, calibration signal, name of lead, filter state and patient’s information. Information including printed waveform length, output measurement parameter, diagnostic conclusion, superposition QRS waveform, histogram, trend chart and interval list, can be set, and with time print function, which meets different requirements. 5)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden. 6)Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm. 7)The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered. 8)1000 cases can be stored by the built-in memory, convenient for case review and statistic. 9)Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report. 10)Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit. 11)External USB keyboard, code scanner, printer and USB storage device can be connected. Performance Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leakage current: <10µA Input impedance: ≥100MΩ(1Hz) Frequency response: 0.01Hz~300 Hz(-3dB) Time constant: ≥3.2s CMRR: >123dB Filter: AC Filter(AC50/60 Hz), EMG Filter (25 Hz/35 Hz (-3 dB)), DFT Filter, Low-pass Filter Recording way: Thermal printing system Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5% within 0.2s~2.0s Gain control(sensitivity):2.5, 5,10, 20, 40, 10/5, 20/10mm/mV, accuracy is ±5%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze. Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze. Manual record: record according to manual record format. Measurement parameters: HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5) amplitude, S(V1) amplitude, R(V5)+S(V1) amplitude Product safety type: Class I type CF defibrillation-proof applied part Polarization resistance voltage: ±950 mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling precision: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: all leads Accuracy of input signal: ±5%. Amplitude quantization: ≤5µV/LSB Interchannel time deviation: <100 µs Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/5000mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories Standard configuration: 1)A lead cable 2)A limb electrode 3)A chest electrode 4)A thermal recording paper 5)A power cord 6)An earth wire 7)A user manual By paypal or by bank By usps : Generally, about 2-9 days Buy Safe Product! The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923,and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved Taxes, Customs & Duties There are not extra taxes, VAT or other unmentioned payment. You pay us with goods subtotal + shipping cost (not include duties). But you need to pay for the import duties in case that occurred for certain goods. Return - After service We offer 60 days return policy. 100% satisfaction is our goal! 1.All items are brand new ,with 1 years warranty. 2.We will refund the money to you when we get the return items or replace item for you. Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.We have us stock in IL,United States We are looking forward to establishing a successful business relationship with you. Welcome to be our agent. Only english user guide,if you need any other language,please contact me. Introduction E3 is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc. Function 1)High resolution thermal-array output system(8 dots/mm), no adjustment required. Frequency Response is up to 150Hz. 2)Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal. 3)Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing. 4)Support for auto 1×12, auto 1×12+1, auto 2×6, auto 2×6+1, auto 3×4, auto 3×4+1, auto 4×3, auto 3-2+1, auto 3-2, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, paper speed, sensitivity, calibration signal, name of lead, filter state and patient’s information. Information including printed waveform length, output measurement parameter, diagnostic conclusion, superposition QRS waveform, histogram, trend chart and interval list, can be set, and with time print function, which meets different requirements. 5)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden. 6)Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm. 7)The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered. 8)1000 cases can be stored by the built-in memory, convenient for case review and statistic. 9)Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report. 10)Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit. 11)External USB keyboard, code scanner, printer and USB storage device can be connected. Performance Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leakage current: <10µA Input impedance: ≥100MΩ(1Hz) Frequency response: 0.01Hz~300 Hz(-3dB) Time constant: ≥3.2s CMRR: >123dB Filter: AC Filter(AC50/60 Hz), EMG Filter (25 Hz/35 Hz (-3 dB)), DFT Filter, Low-pass Filter Recording way: Thermal printing system Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5% within 0.2s~2.0s Gain control(sensitivity):2.5, 5,10, 20, 40, 10/5, 20/10mm/mV, accuracy is ±5%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze. Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze. Manual record: record according to manual record format. Measurement parameters: HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5) amplitude, S(V1) amplitude, R(V5)+S(V1) amplitude Product safety type: Class I type CF defibrillation-proof applied part Polarization resistance voltage: ±950 mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling precision: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: all leads Accuracy of input signal: ±5%. Amplitude quantization: ≤5µV/LSB Interchannel time deviation: <100 µs Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/5000mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories Standard configuration: 1)A lead cable 2)A limb electrode 3)A chest electrode 4)A thermal recording paper 5)A power cord 6)An earth wire 7)A user manualPAYMENTBy paypal or by bank SHIPPINGBy usps : Generally, about 2-9 days Terms of SaleBuy Safe Product! The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923,and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved Taxes, Customs & Duties There are not extra taxes, VAT or other unmentioned payment. You pay us with goods subtotal + shipping cost (not include duties). But you need to pay for the import duties in case that occurred for certain goods. Return - After service We offer 60 days return policy. 100% satisfaction is our goal! 1.All items are brand new ,with 1 years warranty. 2.We will refund the money to you when we get the return items or replace item for you. ABOUT US Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.We have us stock in IL,United States We are looking forward to establishing a successful business relationship with you. Welcome to be our agent. Only english user guide,if you need any other language,please contact me.
Price: 519 USD
Location: Elk Grove Village, Illinois
End Time: 2024-11-24T08:47:51.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
Number of Channels: 3
Model: E3
MPN: WN20240119017
ECG & EKG Machine Type: Electrocardiograph
Features: Printer
Operation: Digital
Country/Region of Manufacture: China
Intended Use/Discipline: Biological Laboratory, Dental Laboratory, Emergency Medicine, Medical Laboratory, Physical Laboratory