Description: Store Categories Store Categories Categories Other 12V 12000 BTU A/C Kit Split Air Conditioner Fit Cab Truck Bus RV Caravan Vehicle Product Description Electrical Parameters : The frequency conversion main control board has a temperature control air outlet input interface, a brush motor drive interface, an infrared remote control interface, an analog voltage signal output interface, and six mechanical buttons. Table 1-1 Electrical Parameters Item Specification : Input voltage (V): DC Max 15 Display :LED Speed adjust method :4.5V-9V Analog voltage speed adjust Speed control logic :10 level speed control Adapt internal fan :Brush electronic fan Remote control Infrared Low voltage protection default set :10.5V Low voltage protection set range: 9V-12V(interval 0.1V) Low voltage protection default recovery :12V Brush fan speed adjust mode : Speed adjust mode: The brush fan interface adjusts the fan speed by adjusting the voltage duty cycle. After starting up, press the wind speed key to adjust the current 5 speeds of the internal fan. The wind speed is adjustable in 1-5 level in each mode. W orking mode instruction : Control board temperature setting and frequency adjust mode Compressor speed range in each mode of inner unit: Air blow mode/FAN: The temperature cannot be adjusted, and the display shows the ambient temperature. Power saving mode/MAN: The compressor runs at 30%-50% of full speed, and the voltage range of power saving mode is 12V~10V. Economy mode/ECO: The compressor runs at 30%-80% of full speed. The energy-saving mode sets temperature at 10 degrees ,wind speed in 3 levels, and the output voltage varies between 4.5V and 7.5V. Powerful mode/POWER: The compressor runs at 100% full speed, and the speed regulating voltage outputs 9V. The control board is powered on acquiesce in by economy mode . The temperature control probe is placed on the surface of the air outlet of evaporator, and the shutdown protection setting temperature is 3℃. When the temperature sensor is disconnected or damaged by an open circuit, the control board will work in sensorless mode, and the display willindicateE-C failure. adiust the output signalto nrevent frost. Brush fan speed adjust mode : Speed adjust mode: The brush fan interface adjusts the fan speed by adjusting the voltage duty cycle. After starting up, press the wind speed key to adjust the current 5 speeds of the internal fan. The wind speed is adjustable in 1-5 level in each mode. Control panel function button instruction : Control panel operation logic: A Power key: Short press to turn on, short press again to turn off。 B Speed up key: Increase in air supply 。 C Speed lower key: to lower the air supply D Mode key: Cycle and hold for one second to switch modes: air blow, power saving, economy, strong wind; long press for 3 seconds to enter the low voltage adjustment state, after adjusting the low voltage protection value, long press the mode button for 3 seconds to remember and exit the low voltage setting E Temperature higher key: Increase the set temperature , and adjust the low-voltage protection value to increase by 0.1V. F Temperature lower key: lower the set temperature , and adjust the low-voltage protection value to lower by 0.1V. G low voltage protection value, low voltage recovery value adjustment: Long press the mode key for 10 seconds to enter the adjustment interface (---), adjust the temperature plus and minus keys to set the low voltage protection value. Fault indication description : low-voltage protection, the power supply voltage is lower than the set value (default: 21.5V), the battery low indicated red light will be on, the fan stops output in the low-voltage state, the analog voltage of the frequency modulation line stops output, and the external unit enters the standby state and stops working. When the voltage exceeds again to low voltage recovery value (default: 25.5V), the system restarts and resumes operation. When the control board detects a fault, it stops working, the fault icon flashes, and the fault code will be displayed on the digital display. The meaning of the code is as follows: E-C: Temperature probe failure E-1: Low voltage protection. E-2: Controller over current protection. E-3: Controller locked-rotor protection. E-4: Controller low voltage protection. . E-5: Poor system cooling. E-7: Phase failure Payment Policy Shipping Policy Returns Policy Contact Us Payment Policy We accept PayPal only. Payment must be cleared within 3 business days after placing the order Shipping Policy We will process your order within the specified time, please be patient; Normally,we will spot check whether the logistics is normal, and we guarantee that all orders have been sent out. If you have not received your goods for a long time, please contact us in time, we will be resp onsible for you to solve the problem. Returns Policy Return is accepted within 30 days after the buyer's receiving the item. If you need return, let us know the detailed problem and send us some pictures for confirmation. Then get a address for return or refund .But we don't accept artificial damage of the items. Manufacturer's limited Warranty for defective items. Contact Us If you received your item find there are something wrong or loss something,pls don't worry,just feel free to contact us, We have been a professional eBay seller for years. Hopefully you can leave positive feedback when you receive your items. If you do, I will be happy all day. If you have any problem with the product, please do not hurry to leave a negative feedback clearly what the problem is and send photo together,we will reply you within 24 hours, of course we will actively solve your problem to get your satisfaction, thank you! Copyright © 2023 Dianxiaomi
Price: 629.99 USD
Location: CA
End Time: 2024-09-15T03:26:56.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
Returns Accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Treeligo
Low voltage protection default set: 10.5V
BTU: 12000 BTU
Rated Voltage (V): DC 12V
Low voltage protection default recovery: 12V
Color: White
Fuel: Electricity
Input voltage (V): DC Max 15
Manufacturer Part Number: Does not apply
Speed adjust method: 4.5V-9V Analog voltage speed adjust
Low voltage protection set range: 9V-12V(interval 0.1V)
Remote control: Infrared